Type | Contact Arran- gement
| Rated Voltage ( E )
| Coil Resistance
| Rated Power Consumption
| Operation Characteristics
|
Voltage Variation Range 90 to 110%E (cold/ hot start within the range of service temperature)
| Operating Voltage
| Releasing Voltage
| Maximum Allowable Voltage
|
75%E or less (+20℃ Cold Start)
| 90%E or less (cold/ hot start within the range of service temperature)
| NO:22.9%E or greater NC:10%E or greater (+20℃ Cold Start)
| 5 to 60%E (cold/ hot start within the range of service temperature)
| (+20℃ Cold Start)
| 140%E (cold/hot start within the range of service temperature)
|
Medium-Capacity | RZDR-G10S/D12 | 1NO
| DC12V | 405Ω
| Approx.0.4W | DC10.8V to DC13.2V
| DC9.0V or less
| DC10.8V or less
| DC2.748V or greater
| DC0.6V to DC7.2V
| DC20.4V | DC16.8V |
RZDR-G01S/D12
| 1NC
| 295Ω | Approx.0.5W | DC1.2V or greater
| DC18.0V |
RZDR-G10S/D24 | 1NO
| DC24V | 1520Ω | Approx.0.4W | DC21.6V to DC26.4V
| DC18.0V or less | DC21.6V or less
| DC5.496V or greater
| DC1.2V to DC14.4V | DC40.8V | DC33.6V |
RZDR-G01S/D24
| 1NC
| 1160Ω | Approx.0.5W | DC2.4V or greater
| DC36.0V |
RZDR-G10S/D48
| 1NO
| DC48V | 5530Ω | DC43.2V to DC52.8V
| DC36.0V or less
| DC43.2V or less
| DC10.992V or greater
| DC2.4V to DC28.8V | DC81.6V | DC67.2V |
RZDR-G01S/D48
| 1NC
| 4060Ω | Approx.0.6W | DC4.8V or greater
| DC72.0V |
Large-Capacity
| RZDR-E10S/D12 | 1NO
| DC12V | 250Ω | DC10.8V to DC13.2V
| DC9.0V or less
| DC10.8V or less
| DC2.748V or greater
| DC0.6V to DC7.2V | DC26.4V | DC16.8V |
RZDR-E01S/D12
| 1NC
| 285Ω | DC1.2V or greater
| DC18.0V |
RZDR-E10S/D24
| 1NO
| DC24V | 1020Ω | DC21.6V to DC26.4V
| DC18.0V or less
| DC21.6V or less
| DC5.496V or greater
| DC1.2V to DC14.4V | DC52.8V | DC33.6V |
RZDR-E01S/D24 | 1NC
| 1080Ω | DC2.4V or greater
| DC36.0V |
RZDR-E10S/D48 | 1NO
| DC48V | 3980Ω | DC43.2V to DC52.8V
| DC36.0V or less
| DC43.2V or less
| DC10.992V or greater
| DC2.4V to DC28.8V | DC105.6V | DC67.2V |
RZDR-E01S/D48 | 1NC
| 3640Ω | Approx.0.7W | DC4.8V or greater
| DC72.0V |
Note:1. Values tabulated above indicate operations at ambient temperature of +20℃.
2. Coil resistance values can vary by ±10%.
3. Maximum allowable voltage is the maximum value that can be applied to the coil in consideration of its thermal degradation and insulators in the relays. This is not a continuous allowable voltage.
4. Type RZDR-G01S and RZDR-E01S may erroneously operate if the maximum allowable voltage is exceeded even for a short time.